Specifications
General | |
Manufacturer | Insteon |
Manufacturer Product No. | 2477SR |
UPC | 813922018073 |
FCC ID | SBP2477S |
Patent No. | U.S. Patent No. 7,345,998, International patents pending |
Certification | Safety tested for use in USA and Canada (ETL #3017581) |
Warranty | Limited 30 Day Warranty |
Operation | |
Operation Modes | Insteon |
Multi-Way Circuit Support | One SwitchLinc Relay controls load, cross-link any number of SwitchLincs or other Insteon Controllers |
Setup Memory | Non-volatile EEPROM |
Insteon Features | |
Insteon Addresses | 1 |
Insteon Links | 400 responder groups and 1 controller group |
Maximum Scene Memberships | 400 (combined controller + responder) |
Scene Commands Supported as Controller | On | Off Fast-On | Fast-Off Begin Brighten | End Brighten Begin Dim | End Dim |
Scene Commands Supported as Responder | On | Off Fast-On | Fast-Off |
Software Configurable | Yes |
Radio Frequency | 915 MHz |
Insteon Powerline Frequency | 131.65 KHz |
Insteon Minimum Transmit Level | 3.2 Vpp into 5 Ohms |
Insteon Minimum Receive Level | 10 mV |
Insteon Messages Repeated | Yes |
RF Ranage | >100' (depending on your home’s construction) |
Mechanical | |
Paddle Type | True rocker action |
Wire Nuts | 4 |
Wires | Line (Hot) - Black, 12 AWG Neutral - White 18 AWG Load - Red, 12 AWG Ground - Bare Copper, 12 AWG |
Mounting | Standard, single-gang wall box |
Set Button | Clear |
Air Gap | Set button when pulled out |
Plastic | UV stabilized polycarbonate |
Beeper | Yes |
Setup LED | 1 red/green dual-color |
Operating Conditions | Indoors, 32-104°F, up to 85% relative humidity |
Dimensions | 4.1" H x 1.78" W x 1.47" D |
Weight | 4.2 oz |
Electrical | |
Supply Voltage | 100-277VAC +/- 10%, 50/60Hz auto-detected at power-up |
Neutral Wire | Required |
Power Wire Leads | 6", 12 AWG, stranded, 600V, 105°C insulation, ends stripped and tinned, Line (black), Load (red), 18 AWG Neutral (white) |
Maximum Load | 17 Amp resistive capacity (100-277 VAC) 1,800 Watt incandescent capacity (100-277 VAC) 1 HP motors (at 120 VAC only) 10 Amps ballast |
Surge Resistance | Up to 500 VAC |
Retains All Settings without Power | Yes, saved in non-volatile EEPROM |
Standby Power Consumption | <1 Watt |
Safety Approved | ETL (Intertek Testing Services) |