General
Manufacturer Insteon
ManufacturerProduct No. 2477DH
UPC 813922011005
Patent No.
Certification Safety tested for use in USA and Canada (ETL #3017581)
Operation
On-Levels 32 locally, increments of 1% with software
Ramp Rates (full-ON to full-OFF) 0.125 to 9 seconds if programmed locally,
0.125 seconds to 8 minutes if programmed remotely
LED Indicator 9 White LEDs,
Optional Green, Blue, Amber, or Red with item 2400L Kit
Operation Modes Insteon
Multi-Way Circuit Support One SwitchLinc Dimmer controls load,
Cross-Link any number of SwitchLinc Dimmers or other Insteon Controllers
Setup Memory Non-volatile EEPROM
Insteon Features
Insteon Addresses 1 hard-coded out of 16,777,216 possible
Insteon Links 417
Insteon Powerline Frequency 131.65 kHz
Insteon Minimum Transmit Level 3.2 Vpp into 5 Ohms
Insteon Minimum Receive Level 10 mV
Insteon Messages Repeated Yes
Radio Frequency 915 MHz
Ramp Rates (full-ON to full-OFF) 0.125 to 9 seconds if programmed locally,
0.125 seconds to 8 minutes if programmed remotely via software
Mechanical
Paddle Type True rocker action
Color -
Wire Nuts 4
Mounting Mounts in a single or multiple-ganged junction box. Control 200 W less load for each immediately adjacent Dimmer Switch installed. For example, 600 W load control becomes 400 W with another dimmer to the immediate right or left. Use a triple-gang box with a mechanical switch in the center to avoid de-rating.
Operating Conditions Indoors, 32 to 104° F, up to 85% relative humidity
Dimensions 4.1" H x 1.8" W x 1.2W" D
Weight 3.6 oz
Electrical
Supply Voltage 100-277 Volts AC +/- 10%, 50/60 Hertz, single phase
Neutral Wire Required
Power Wire Leads 6", 18 AWG, stranded,600V, 105° C insulation, ends stripped and tinned, LINE (black), LOAD (red), NEUTRAL (white)
Maximum Amps 8 amps
Ground Lead 6", 18 AWG, stranded, bare copper
Load Types Wired-in incandescent lighting devices
Maximum Load 1000 Watts
Power Consumption 0.56 Watts
Heat Dissipation Four heat dissipation fins integrate into the body of the switch. Individual fins can be permanently detached from the switch if fins interfere with installation. Removal of each individual fin will reduce rated switch capacity by 100W.