Specifications
General | |
Manufacturer | Insteon |
Manufacturer Product No. | 2450R |
UPC | 813922018158 |
FCC ID | SBP26722A |
Certifications | FCC, IC Canada |
Patent No. | Patent No. 7,345,998, International patents pending) |
Warranty | 2 Years |
Insteon Features | |
Insteon Addresses | 1 hard-coded out of 16,777,216 possible |
Insteon Links | 417 |
Insteon Powerline Frequency | 131.65 KHz |
Insteon Minimum Transmit Level | 3.2 Vpp into 5 Ohms |
Insteon Minimum Receive Level | 10 mV |
Insteon Messages Repeated | Yes |
Operation | |
Status LED | Yes |
Insteon RF mesh repeater | White (Bright when relay closed, dim when relay open) |
Sensor Status LED | Green (On when sensor closed, Off when sensor open) |
Set Button | Toggles output relay On/Off. Also used for setup |
Momentary Duration | Locally Adujtable: 2 Seconds to 30 Minutes Software Adjustable, .2 Seconds - 105 minutes |
Operation Modes | Insteon |
Multi-Way Circuit Support | Yes |
Setup Memory | Non-volatile EEPROM |
Mechanical | |
I/O Terminals | 5V DC (10mA) GND Sense N/O Common (28-16 gauge wire) |
Input jack | 1/8" mini jack input (GND, Sense) |
Input Type | Contact closure only |
Output Relay Capacity | Standard, single gang wall box |
Operating Conditions | Indoors: 32 to 104° up to 85% relative humidity |
Dimensions | 4.5" H x 2.5" W x 1.5" D |
Weight | 4.6 oz |
Electrical | |
Voltage | 120 Volts AC +/- 10%, 60 Hertz, single phase |
Sensor Input | 1/8" mini jack input (GND, Sense) |
Power Plug | 3-pin grounded |
Retains all settings without power | Yes, saved in non-volatile EEPROM |
Pass-through Outlet | Uncontrolled 3-prong (with ground), 120V, 15A |
Power Consumption | 0.93 Watts |
Certification | Safety tested for use in USA and Canada |