I/O Linc - Insteon Low Voltage / Contact Closure Interface ( 1 In / 1 Out )
Share Share Share Share Share

Insteon Remote Control Plug-in Low Voltage Controller

Expand your Insteon Network to monitor and control low voltage and contact closure devices
  • Monitor and control pool valves, electric door strikes, garage doors and more using your Insteon network
  • 4 output relay modes allow you to control many different types of devices
  • Control Insteon lights and appliances using standard sensors
  • Contains 1 sensor input and 1 output relay (NO/NC)
  • For control from an Insteon Mini Remote, you will need a Range Extender or other dual-band Insteon devices*
  • Can be used with an Insteon Hub however the included IOLinc module communicates via powerline only, so you may need a Range Extender or other dual-band Insteon devices*
  • Award-winning Insteon technology provides superior performance and reliability
* The included Insteon IO Linc module communicates over powerline only, which may cause issues if you are trying to remotely operate Insteon devices on a different electrical phase (circuit) or from a Mini Remote. We recommended adding a Range Extender on the same phase to bridge the IO Linc module with Insteon RF-only or Dual-band devices.

Item #: 2450 IN STOCK - SHIPS TODAY

$45.99
REWARDS: 45 points
  • Details
  • Specs
  • Reviews
  • Manuals
  • What's Included
  • The latest Insteon plug-in module, I/O Linc, lets you monitor and control any low voltage devices such as alarm sensors, electric door strikes, and contact closures as part of your Insteon home automation network. With one dry-contact sensor input you can control many Insteon devices throughout the house. Plus, use the built-in single-pole double-throw (SPDT) switch, connect any low voltage-powered device for continuous or momentary operation. Create your own remote-control door lock using an electric door strike and power supply or use a security sensor turn Insteon controlled lights on or off.

    Required Accessories

    Sensor wire: 16 - 28 gauge wire fits, but 20 - 22 gauge recommended

    I/O Linc's flexible output relay can control many different types of low voltage devices, from pool valves to electric door strikes to garage doors due to its different relay modes. When controlling devices like pool valves, you will want the ability to leave it on for an extended period of time, giving it plenty of time to fill the pool. As it approaches the desired water level, then you can remotely turn it off. For devices like electric door strikes, set I/O Linc's output relay to momentary, allowing you open the front gate using a RemoteLinc or any other Insteon controller. A third version of I/O Linc's momentary mode allows you to remotely press your garage door button with an Insteon On command, but only if your garage is currently closed. This allows you to open your garage with On command and close it with an Off command. Because I/O Linc uses a garage door sensor to know whether the door is open or closed, it only controls the garage when it needs to.

    Controlling Two Separate Loads

    With the addition of a DPDT Relay Board, the I/O Linc is capable of switching two separate loads on and off together. In this configuration, the I/O Linc could control two different loads of varying voltages (i.e. one high voltage and one low voltage load) or two higher current loads (up to 7A @30VDC each).

  • General
    Manufacturer Insteon
    Manufacturer Product No. 2450
    UPC 689076403542
    FCC ID SBP26722A
    Certifications FCC, IC Canada
    Patent No. Patent No. 7,345,998, International patents pending)
    Color White
    Warranty 2 Years, limited
    Operation
    Status LED Yes
    Insteon RF mesh repeater White (Bright when relay closed, dim when relay open)
    Sensor Status LED Green (On when sensor closed, Off when sensor open)
    Set Button Toggles output relay On/Off. Also used for setup
    Momentary Duration Locally Adujtable: 2 Seconds to 30 Minutes
    Software Adjustable, .2 Seconds - 105 minutes
    Operation Modes Insteon
    Multi-Way Circuit Support Yes
    Setup Memory Non-volatile EEPROM
    Insteon Features
    Insteon Addresses 1 hard-coded out of 16,777,216 possible
    Insteon Links 417
    Insteon Powerline Frequency 131.65 KHz
    Insteon Minimum Transmit Level 3.2 Vpp into 5 Ohms
    Insteon Minimum Receive Level 10 mV
    Insteon Messages Repeated Yes
    Mechanical
    I/O Terminals 5V (10mA)
    GND
    Sense
    N/C
    N/O
    Common (28-16 gauge wire)
    Input jack 1/8" mini jack input (GND, Sense)
    Input Type Contact closure only
    Output Relay Capacity 5A @ 30 Volts (AC or DC)
    Operating Conditions Indoors: 32 to 104°
    up to 85% relative humidity
    Dimensions 4.5" H x 2.5" W x 1.5" D
    Weight 4.6 oz
    Electrical
    Supply Voltage 120 Volts AC +/- 10%, 60 Hertz, single phase
    Sensor Input 1/8" mini jack input (GND, Sense)
    Power Plug 3-pin grounded
    Retains all settings without power Yes, saved in non-volatile EEPROM
    Pass-through Outlet Uncontrolled 3-prong (with ground), 120V, 15A
    Power Consumption 0.93 Watts
    Certification Safety tested for use in USA and Canada
  • Reviews 151 - 156 of 156

    Page:
    1. 1
    2. ...
    3. 12
    4. 13
    5. 14
    6. 15
    7. 16
    Review of 2450 Review by JAY
    Review of 2450
    Rating

    This unit solved a big issue for me. Monitoring and controlling my garage door status.

    Posted on 3/11/2009

    Review of 2450 Review by JAMES
    Review of 2450
    Rating

    Works just fine. It's the insteon equivalent of the old X10 "powerflash" module.

    Posted on 2/21/2009

    Review of 2450 Review by DOUGLAS
    Review of 2450
    Rating

    These seem to function ok, but medium sized and larger installations require several more of these than you might expect from the product description. We are at 5 units in a 5,000sqft home and probably need two more to increase communication reliability.

    Posted on 2/12/2009

    Review of 2450 Review by DOUGLAS R
    Review of 2450
    Rating

    These seem to function ok, but medium sized and larger installations require several more of these than you might expect from the product description. We are at 5 units in a 5,000sqft home and probably need two more to increase communication reliability.

    Posted on 2/12/2009

    Review of 2450 Review by CLARENCE
    Review of 2450
    Rating

    Works well and was easy to setup.

    Posted on 2/9/2009

    Review of 2450 Review by DAVE
    Review of 2450
    Rating

    linked and programmed easily using isy 26. home run.

    Posted on 2/4/2009

    Leave a Review

    Only registered users can write reviews. Please, log in or register

    • 1x - I/O Linc
    • 1x - 1.5mm flathead screwdriver
    • 1x - Quick Start Guide

Please wait...