In-LineLinc Relay - INSTEON 2475S2 Remote Control In-Line On/Off Switch with Sense
Share Share Share Share Share
Rewards: 118 Points

In-LineLinc Relay - INSTEON 2475S2 Remote Control In-Line On/Off Switch with Sense

Integrate Existing 120-volt Sensors into Your INSTEON Network
INSTEON

Item #: 2475S2

Product is unavailable

$59.99
  • Details
  • Specs
  • Reviews
  • What's Included
  • Built with a Quieter Relay
    Because the In-LineLinc Relay is built with a much quieter relay than most remote-control ON/OFF relays, it has a click that's more than 80 percent quieter than traditional relay switches. This allows you to control lights and other non-dimmable devices remotely without waking up the baby, annoying other family members, or sending your cat fleeing across the room. The click of the In-LineLinc Relay's internal relay is barely audible.

    Generates Less Heat
    Unlike triac-based switches, the In-LineLinc Relay uses a hard-contact relay to control the load. Other switches use a semiconductor that absorbs about two volts of power and dissipates the heat through the front of the module. By using a relay, the device runs cooler and full voltage gets to the load.

    Compatibility
    The In-LineLinc Relay is fully INSTEON compatible and X10 ready. Homeowners with existing X10 networks can easily migrate to an INSTEON network without having to discard all their existing X10 devices. X10 ready means that the In-LineLinc Relay can respond to X10 commands from an X10 controller and it can send X10 commands to X10 devices. Please note that INSTEON devices repeat INSTEON signals but not X10.

    Non-Volatile Memory
    All In-LineLinc Relay settings are stored in non-volatile memory and are not lost during power failures. Additionally, in the event of a power loss, the In-LineLinc Relay will return to its last on/off state when power is restored.

    Certifications and Warranty
    All In-LineLinc products are safety approved. The factory for SmartLabs Design Products is ISO9001 certified. Because of this passion for quality, Smarthome stands behind the entire In-LineLinc line of products with a full 2-year warranty.


  • Specifications

    General
    Brand:INSTEON
    Manufacturer Product No.:2475S2, INSTEON In-LineLinc Relay (Non-Dimming) w/ Sense
    UPC:718122390618
    Patent No.:U.S. Patent No. 7,345,998, International patents pending
    Warranty:2 years, limited
    Operation
    Operation Modes:INSTEON only, X10 only, INSTEON and X10 Combo Mode
    Combo Mode Message Order:INSTEON, INSTEON confirmations, X10
    LED Indicator:Off when load is on and vice versa
    Sense Behavior:When 120V is applied to Sense wire, In-LineLinc turns on load and all linked INSTEON devices. Off when power is removed.
    Multi-Way Circuit Support:Yes, as a receiver and as a controller
    Setup Memory:Non-volatile EEPROM
    INSTEON Features
    INSTEON Addresses:1 hard-coded out of 16,777,216 possible
    INSTEON Links:417 out of 16,777,216 possible
    INSTEON Powerline Frequency:131.65 KHz
    INSTEON Minimum Transmit Level:3.2 Vpp into 5 Ohms
    INSTEON Minimum Receive Level:10 mV
    INSTEON Messages Repeated:Yes
    Mechanical
    Wire Nuts:6 included
    Mounting:Mounts in single or multiple-ganged junction box or fixture such as a ceiling fan.
    Operating Conditions:Indoors, 32 to 104
  • Reviews 1 - 10 of 82

    Page:
    1. 1
    2. 2
    3. 3
    4. 4
    5. 5
    6. ...
    7. 9
    Review of 2475s2 Review by Frank_YYZ
    Review of 2475s2
    Rating

    Works as advertised, but it could be so much better. If one could configure the sense input and relay output to be independent of each other like the IOLinc, one could control the load independently of the sense input.

    For example, one could detect motion any time day or night. One could then use their house controller to decide whether to turn on the load. One could also turn the load on or off at any time, independent of the sensor while retaining the ability to sense motion. This would be a trivial firmware change and shouldn't require any h/w mods to the module.

    It would currently take two in-line modules to accomplish this and there is no way these would fit into an existing junction box.

    Posted on 4/17/2013

    Review of 2475s2 Review by BOB
    Review of 2475s2
    Rating

    Good product, however the sense function is very sensitive to what voltages it must see in order to "sense".
    The sense leads must return to zero volts, and go to ~120 volts for a valid "sense" function, which makes connecting many of the currently available PIR devices impossible.

    Posted on 2/24/2013

    Review of 2475s2 Review by MICHAEL
    Review of 2475s2
    Rating

    Works well, but as reported in another post does not work with The Home Depot Heath Motion Detector but works with the ACE Heath Motion detector

    Posted on 1/18/2013

    Review of 2475s2 Review by RICHARD
    Review of 2475s2
    Rating

    Have tested it in the house and works fine, I need it to warm up before installing it in my shed.

    Posted on 12/26/2012

    Review of 2475s2 Review by MARK
    Review of 2475s2
    Rating

    Have not had the chance to work with this yet, but it is a little large to fit in a standard J Box along with the wire.

    Posted on 12/26/2012

    Review of 2475s2 Review by TIM
    Review of 2475s2
    Rating

    I've got a high-end motion sensor. Output of that to input of 2457s2 and now I have a high-end Insteon motion sensor. Rated good because it works as expected. if it lasts a few years it'll be worth an excellent.

    Posted on 12/5/2012

    Review of 2475s2 Review by JOSEPH
    Review of 2475s2
    Rating

    Perfect to control a device, yet still allow a motion sensor to do the same.

    Posted on 12/1/2012

    Review of 2475s2 Review by JOERG
    Review of 2475s2
    Rating

    Works great! Easy to install in a single-gang box.

    Posted on 11/14/2012

    Review of 2475s2 Review by JOSEPH
    Review of 2475s2
    Rating

    Great Product. Does what it's meant to do.

    Posted on 11/10/2012

    Review of 2475s2 Review by WAYNE
    Review of 2475s2
    Rating

    The small size proved important. I was able to mount it in the junction box behind an existing mechanical timer and now I can link to the timer's on and off, can I can override it. (Wire the yellow sense wire to the timer's red output, and move the timer's load to this relay's red wire.)

    Posted on 10/14/2012

    Leave a Review

    You're reviewing: In-LineLinc Relay - INSTEON 2475S2 Remote Control In-Line On/Off Switch with Sense

    • 1 star
      2 stars
      3 stars
      4 stars
      5 stars

    * Required Fields

  • INSTEON In-LineLinc On / Off Module (Non-dimming) w/ Sense
  • 6 Wire Nuts
  • Quick Start Guide
  • place your order by 3pm PT for same day shipping

    Please wait...

    smarthome

    Item has been added to your cart
    smarthome

    Item has been removed from your cart