HomeSeer ADIO-100 Input Output Controller System Interface

Monitor and Control Low Voltage Wired Sensors and Devices
  • Use with HomeSeer to monitor up to 8 analog sensors
  • 8 digital ports may be used to detect contact closures
  • Digital ports may also be configured to output 5 volts to various devices
  • Integrates with HomeSeer Controllers and the ADIO-100 plug-in (each sold separately)


REWARDS:149 points
  • Details
  • Specs
  • Reviews
  • Manuals
  • What's Included
  • The HomeSeer ADIO-100 Input Output Controller System Interface allows for low voltage inputs (sensors, triggers, etc.) and outputs (door strikes, sirens, etc.) to be integrated with HomeSeer systems. You can use a variety of analog sensors to monitor light levels, temperature, humidity, energy, sound and other data. Events may be triggered on the changing values of these sensor devices. Similarly, you can use digital sensors, such as door or window contact switches to monitor status of things opening and closing; or use it in parallel with an existing security panel to monitor the status of security peripherals, such as motion sensors. The digital output allows you to have events trigger basedon the changing status if the analog and digital inputs. For example you can power LEDs, piezo buzzers or sirens or other low voltage, low current devices.

    Suggested Uses
        •  with Dakota Alert wireless receiver to trigger automation events when outdoor sensors detect vehicles, people, animals, etc.
        •  with simple switch buttons (like door bells) to trigger automation events.
        •  with wired door or window magnetic switch sensors to trigger automation events.
        •  with analog sensors to monitor light levels, temperature, humidity, etc.
  •  Specifications

     Brand  Homeseer
     Manufacturer Part Number  ADIO-100
     UPC Code  610585163924
     Inputs / Outpuits  • 8 analog inputs for use with a variety of sensors
     • 8 user configurable digital ports (input or 5v output)
     Analog Input Voltage  10 VDC Max
     Digital Input Voltage  10 VDC Max
     Power  12 VDC
     MPU  Microchip PIC18F4455
     MPU Clock  32 Mhz
     Interface  RS-232 (single ended)
     Baud  9600, 19200, 57600, 115200 (DIP switch selectable)
     LED  Bicolor diagnostic LED
     Watchdog  MPU has built-in watchdog timer
     POR  MPU has built-in watchdog timer
     Brownout  MPU brownout detection circuitry built-in
     Temperature  0° C to 70° C (32° F to 158° F) Commercial Temperature Range
     PCB  R4
     Power  7.5VDV to 15.0 VDC (approx. 50 ma nominal current)
     Power  7.5VDV to 15.0 VDC (approx. 50 ma nominal current),24 VDC maximum 100 ma
     current draw