Overview
|
- Interface to serial-controlled devices
- Output-only data transfer
Essential Info
The Serial Bobcat provides an interface from an ADICON system to serial-controlled devices. The data transfer is output only from the Bobcat; it will not receive data. Messages stored in the ASCII Bobcat are entered using the ASCII Messages screen accessible from the CPUXA Access screen in C-Max, which is also used to change a parameter value. LED codes indicate activity.
Manuals/Software
What's Included
Cable Instructions
|
More Info
|
Once all messages have been entered, select the module number for the ASCII Bobcat and click the Send To button to download the messages into the ASCII Bobcat. The ASCII Messages screen will disappear, and the CPUXA Access screen will show the progress of the download. ASCII Bobcat messages may be transmitted manually using the Transmit ASCII Message screen available in the Module Utilities of the CPUXA Access screen.
A BOBCAT RS-485 Serial Interface is also available and is sold separately.
|
Specifications
|
Specifications | | Applied Digital Product No.: | BOBCAT RS-232 | | Dimensions: | 2.5"L x 1.35"W x 0.6"H; 6' DB-9 male cable | | ASCII Message Capacity: | 128 messages, 32 bytes per message | | I/O: | ADNET: 2 screw terminals; power: 2 screw terminals (up to 14 AWG); 9 pin DB-9 serial connector | | Power: | Input Voltage: 9 - 12V DC or AC | | Input Current: | Max 30mA | | Operating Temperature: | 32º F to 158º F (0º C to 70º C) |
|