- Trigger devices based on high or low humidity level (set by user)
- Self-contained unit
- Uses a sold state transducer
- Great for keeping your home comfortable and safe
Essential Info
Be aware of humidity problems as soon as they start with this humidity sensor that triggers I/O Linc-connected lamps to flash. The Minotaur Engineering IHS Humidity Sensor/Controller for INSTEON I/O Linc triggers based on a humidity level that you set (15% to 95%) and sends a signal to any INSTEON receiver in range via an I/O Linc (sold separately). The sensor is completely self contained and uses a solid state transducer preset at the factory. There are three leads extending from the sensor. The sensor should be placed in a location that will protect it from moisture and direct sun to accurately reflect the ambient humidity.
Important notes:
- Smarthome offers technical support on this product. We offer (2) ways to contact us for technical support: CHAT (homepage button: Mon-Fri 9:00am-6:00pm ET) or Phone: 1-800-762-7846 (Mon-Fri 9:00am-9:00pm & Sat 10:00am-4:00pm ET)
- Defective exchanges for identical item within Manufacturer’s warranty period.
Manuals/Software
What's Included
1x - Minotaur Engineering IHS Humidity Sensor/Controller for INSTEON I/O Linc 1x - Owner's Manual
|
More Info
|
The INSTEON Humidity Sensor/Controller connects to the I/O Linc unit via three leads on a 5-foot cable. The IHS senses the ambient room humidity using a sophisticated semiconductor device. It draws power from the I/O Linc module and triggers based on a user setting. Humidity will vary from room to room and from one area of a room to another. Ventilation and airflow will affect relative humidity. The IHS has a delay/ spread of about 3% RH. Always allow enough time for the sensor to acclimate to current room conditions before expecting it to trigger accurately.
NOTE: Observe polarity in connecting to the I/O Linc. Incorrect wiring to the I/O Linc can destroy the device. If the I/O Linc and/ or INSTEON Responder have been used previously, they need to be set back to their factory settings prior to use. For residential use only. Do not submerge. Best operating temperature range is 55°F to 95°F.
1) Connect the Shiny Metal sensor wire to the I/O Linc "GND" Terminal (2nd from the left screw terminal.)
2) Connect the Black wire to the I/O Linc "SENSOR" Terminal (3rd from the left screw terminal.)
3) Connect the Red wire to the I/O Linc "5v" Terminal (1st from the left screw terminal.)
4) Plug your I/O Linc into an un-switched outlet. (The I/O Linc LED will come on.)
5) Using a small screwdriver on the blue trimmer potentiometer located on the exterior of the sensor, turn the dial all the way to the left (counterclockwise) to get the humidity to trigger a device ON at or above the set humidity (Or OFF below a set humidity).
6) Press and hold the I/O Linc Set button until it beeps (about 3 seconds.)
7) Plug your INSTEON Responder (receiver) into an un-switched wall outlet.
8) Now Press and hold the Set button on your INSTEON Responder (the device you wish to control) for at least 3 seconds. (The I/O Linc will beep and its Status LED will return to steady "on" to confirm linking.) The INSTEON device will be "triggered" based on being at a higher humidity than selected.
9) Plug devices you wish to control into your Insteon Responder.
10) Set your trigger humidity based on the instructions on the next page.
|