Overview
|
- Fully-programmable system offers extensive remote monitoring and control capability
- Alert notification via user recordable voice, fax, modem, pager and e-mail
- Operate, program and receive reports via a web interface
- Eight universal inputs, built-in power failure detection and a programmable output
- LED status indicators
Essential Info
Protect and monitor your home, vacation home, cabin or cottage, even when you can't be there! Doing so is made easy and convenient with the use of a Sensaphone 2000. The device can monitor equipment and environmental conditions using up to eight universal inputs and its built-in power failure detection. It also features a programmable output that will attempt up to 32 contacts whenever an abnormal condition arises. It can use a wide variety of notification options including user recordable voice, fax, modem, numeric pager, alphanumeric pager and Internet e-mail. In addition, you can generate a web page based on the information received and stored in the device and post it on the Internet at a programmable time interval.
The Sensaphone 2000 unit will monitor and send an alert on eight universal inputs including motion detection, temperature, leak detection, humidity and smoke detection to name a few; sensors sold separately. The main unit can be programmed via a local serial port or remotely via an internet connection. A built-in relay output can be controlled manually through the included software, remotely via touch-tone telephone, or automatically using programmable high and low set points. On the front of the unit are LED indicators to show the operating status. The Sensaphone 2000 is a convenient way to monitor your property while you aren't there and to receive instant alerts in multiple ways whenever conditions reach levels out of the norm letting you know of the concern as soon as it happens.
This product is also available with a NEMA 4X Enclosure (SKU 7009).
Manuals/Software
What's Included
Sensaphone 2000 Remote Home Monitoring and Control System Power Adapter Owner's Manual
|
More Info
|
Monitoring Sensaphone 2000 allows you to select up to eight inputs, digital or analog, to monitor conditions such as room temperature, outside temperature, power failure, humidity, tank levels, tank temperature, pressure, flow rates, flooding, HVAC controllers, etc. When there's a problem, it alerts you immediately. Whatever you need to know, the Sensaphone 2000 can tell you. You can program ranges to suit your specific monitoring requirements, and all programming can be done locally or from virtually any remote location. Digital functions include open/closed dry contact input and/or pulse counting. Analog can be read as a percentage or via a user-defined lookup table.
Immediate Access All it takes is a phone call to receive a voice status report or a data connection for more detailed information. You can check on any site and access critical information at any time from anywhere. The knowledge you need is always just a phone call away.
Destinations The Sensaphone 2000 will call up to 32 telephone numbers or e-mail addresses (both referred to as destinations) to report alarm conditions or send reports. Destinations can be voice calls, fax machines, computers with modems running Sensaphone 2000 software, e-mail addresses, numeric pagers, or alphanumeric pagers.
Data Logging The unit is capable of performing data logging from the eight universal inputs, power and battery voltage. The data logging is stored in nonvolatile memory. A real-time clock is also included to time stamp logged data and to schedule reports. The unit is capable of sending automatic reports on a programmable time basis (i.e. Send a report every x hours starting at time xx:xx). Reports may be sent via fax or e-mail, and will be sent to all destinations programmed to receive reports. The report comprises a cover page and the unit data, which includes the current conditions of each input, power status and battery condition. If the data logger is enabled and programmed to be sent with reports, a data log report will also be sent at this time. You have the additional option of retrieving the data logger information locally or remotely on demand. You can also have the Sensaphone 2000 call your PC and upload the entire data logger and event logger, storing the information in the Sensaphone 2000 database.
Programming Interface Manager 2000 Windows-programming software is included to allow quick and easy access to all of the unit's programmable parameters. Sophisticated features such as real-time input monitoring, graphical bar and gauge displays, polling of multiple units and a database to store and query data logger information, all combine to provide a complete monitoring system. Internet options for creating web pages and delivering e-mail are also included. The Programming and Operation chapters provide step-by-step instructions on how to use all of the unit's features.
Battery Backup The Sensaphone 2000 includes an internal UPS that automatically switches to battery backup in the event of an AC power failure. The battery in the Sensaphone 2000 is a 6 Volt 3.4AH rechargeable gel cell. This battery will keep the unit operating for approximately 10 hours when fully charged and under normal operating conditions. Note: The unit will not turn on unless AC power is connected, regardless of the condition of the back-up battery.
Line Seizure Line seizure gives the 2000 unit the ability to "seize" the telephone line when it needs to dial out. For example, if an emergency occurs which puts the 2000 in alarm mode, the unit will be able to dial out even if a telephone has been left off the hook. To the right of the PHONE LINE jack is another labeled PHONE EXT. This jack can be used to share a phone line with other devices (telephone, fax machine, modem) and to give the 2000 priority in the event of an emergency. To make use of this feature you must have all the extension devices originate from the PHONE EXT. jack. Whenever the unit must make an alarm phone call, the unit will disconnect any current phone calls and seize the line for its own use. The unit will continue to seize the line until the alarm has been acknowledged.
LED Indicators The LEDs provide on-site alarm and status information. Listed below are descriptions of how the LEDs work. Inputs 1-8 and Power: LED Off: Input OK, LED Blinking: Unacknowledged alarm exists LED On: Acknowledged alarm exists Battery: LED On: Battery condition OK, LED Blinking: Battery condition low, LED Off: Battery very low System-On: LED On: System power on, LED Off : System power off Phone: LED On: Unit is communicating on the phone line, LED Off: Unit is not using the phone line Output: LED On: The output relay is ON, LED Off: The output relay is OFF
Sensaphone 2000 Software Requirements 486 or better computer (Pentium recommended) 10 MB of free disk space 32 MB or more of RAM CD ROM drive Microsoft Windows 98, ME, NT, 2000 or XP Monitor Mouse Modem
WebPage The Sensaphone 2000 software can generate a web page based on the information in your 2000 and post it on the internet at a programmable time interval. The web page can be created in both standard HTML and WML formats; the latter allows viewing on an internet-capable cell phone. The web page will include input and alarm information. If you have more than one Sensaphone 2000, a separate web page will be created for each. The web page is created every time a Sensaphone 2000 unit is polled. In this scenario your host computer would contact one or more Sensaphone 2000s, retrieve the I/O status and alarm information, then create the web page. The software then uploads the web page to a specified server and directory on the World Wide Web. Most internet service providers allocate several megabytes of space on their server for their subscribers to place their own web pages as part of the internet service contract. Contact your internet service provider for information. Note that a typical Sensaphone web page only uses about 60K of storage space. The Web Page feature requires that you have a computer running Windows 95, 98, ME, NT, or 2000. Internet providers which use proprietary software, such as America OnLine, cannot be used. Your internet service provider must support File Transfer Protocol (FTP).
Installation When you receive the unit, carefully remove it from the box. Mounting tabs with holes are provided on the left and right sides of the enclosure. Mount the unit in a position that allows easy access to the input terminal block, battery compartment, on/off switch and the programming port. Also, there must be a power outlet and telephone jack close to the unit.
|
Specifications
|
Specifications | | Manufacturer: | Sensaphone | | Manufacturer Product No.: | FGD-2000 | | Dialing Parameters: | Programmable call list for each inputCall progress monitoring: detect dial tone, busy signals & ringbackProgrammable time between calls: 30 seconds to 60 minutes | | Destinations: | 32 Destinations32-digit phone numbers, 64 character email addressesProgrammable 24x7 call schedule for each Destination | | Inputs: | 8 Universal Inputs & 1 AC PowerNormally Open/Normally Closed dry contact, Pulse Count, Run Time accumulatorCompatible with 2.8K or 10K thermistors4-20mA current loop, or 0-5V DC analog10 bit resolution | | Communication Methods : | Programmable Voice, Fax, Cell Phone/Alpha Pager Text Message, Numeric Pager, E-mail, Web Page | | Custom Voice Messages: | 8 Input messages (4 seconds each), 1 site ID message (6 seconds) | | Data Logging: | 32,000 records, each with time and date stampSelectable Logging Interval: 1 second to 200 hoursSelect channels to log: Inputs 1-8, AC Power, Backup Battery Voltage | | Communication Ports: | RS-232 port for local programmingDB9 female DCE 38,400 bps | | Built-in Fax/Modem: | Data throughput 14,400 bps14,400 bps FaxProtocols: V.32bis, V.32, V.22bis, V.22A/B, V.23, V.21, Bell 212A & 103 | | Local LED Indicators : | Inputs 1-8 Alarm StatusPower AlarmPhoneBattery OK | | Power Requirements : | External transformer 120VAC 60Hz 10W (UL-listed power supply)3.4Ah sealed rechargeable battery (included)10 hour battery backup | | Output Relay : | 1 | | Operating Temp Range : | 0° C - 50° C (32° F - 122° F) | | Humidity: | 0% - 90% relative humidity, non-condensing | | Size: | 12.1" W x 7.2" H x 1.6" D | | Weight: | 3 lbs. | | Certifications: | FCC |
|
|
|
Important notes:
Only defective exchanges for identical item within 30 days of purchase. No other returns allowed on this item. For defective returns after 30 days, please contact the manufacturer.
Manufacturer contact information: Sensaphone Inc, Tel: (877) 373-2700 Ext 260
|