Overview

  • Fully-programmable system offers extensive remote monitoring and control capability
  • Alert notification via user recordable voice, fax, modem, pager and e-mail
  • Operate, program, and receive reports via a web interface
  • Eight universal inputs, built-in power failure detection and a programmable output
  • LED status indicators
  • Comes with in a NEMA 4X enclosure

Essential Info

Protect and monitor your home, vacation home, cabin or cottage, even when you can't be there! Doing so is made easy and convenient with the use of a Sensaphone 2000. The device can monitor equipment and environmental conditions using up to eight universal inputs and its built-in power failure detection. It also features a programmable output that will attempt up to 32 contacts whenever an abnormal condition arises. It can use a wide variety of notification options including user recordable voice, fax, modem, numeric pager, alphanumeric pager and internet e-mail. In addition, you can generate a web page based on the information received and stored in the device and post it on the internet at a programmable time interval. The Sensaphone 2000 unit will monitor and send an alert on eight universal inputs including motion detection, temperature, leak detection, humidity and smoke detection to name a few; sensors sold separately. The main unit can be programmed via a local serial port or remotely via an internet connection. A built-in relay output can be controlled manually through the included software, remotely via touch-tone telephone, or automatically using programmable high and low set points. On the front of the unit are LED indicators to show the operating status. Additionally, this package includes a NEMA 4X enclosure that can be used to protect the Sensaphone 2000 form the harshest of environments. The Sensaphone 2000 is a convenient way to monitor your property while you aren't there and to receive instant alerts in multiple ways whenever conditions reach levels out of the norm letting you know of the concern as soon as it happens.

This product is also available without a NEMA 4X Enclosure.

Manuals/Software

What's Included

  • Sensaphone 2000 Remote Home Monitoring and Control System
  • Power Adapter
  • NEMA 4X Enclosure
  • Owner's Manual
  • More Info

    NEMA 4 and 4X Enclosure
    NEMA 4 industrial enclosures are used in many applications where an occasional washdown occurs or where machine tool cutter coolant is used. They also serve well in applications where a pressurized stream of water will be used. NEMA 4 enclosures are gasketed and the door is clamped for maximum sealing. They have continuous hinges, mounting feet, and padlock hasps. NEMA 4X metal electrical enclosures are made of stainless steel. These NEMA enclosures are used in harsher environments than standard NEMA 4 units. Applications where corrosive materials and caustic cleaners are used necessitate the use of a NEMA 4X enclosure. Applications include food, such as meat/poultry processing facilities, where total washdown with disinfectants occur repeatedly and petro-chemical facilities, including offshore petroleum sites. NEMA 4X industrial cabinets are used when protection from the worst environments is required.

    Monitoring
    Sensaphone 2000 allows you to select up to eight inputs, digital or analog, to monitor conditions such as room temperature, outside temperature, power supply, humidity, tank levels, tank temperature, pressure, flow rates, flooding, HVAC controllers, etc. When there's a problem, it alerts you immediately. Whatever you need to know, Sensaphone 2000 can tell you. You can program ranges to suit your specific monitoring requirements, and all programming can be done locally or from virtually any remote location. Digital functions include open/closed dry contact input and/or pulse counting. Analog can be read as a percentage or via a user-defined lookup table.

    Immediate Access
    All it takes is a phone call to receive a voice status report or a data connection for more detailed information. You can check on any site and access critical information at any time from anywhere. The knowledge you need is always just a phone call away.

    Destinations
    The Sensaphone 2000 will call up to 32 telephone numbers or e-mail addresses (both referred to as destinations) to report alarm conditions or send reports. Destinations can be voice calls, fax machines, computers with modems running Sensaphone 2000 software, e-mail addresses, numeric pagers, or alphanumeric pagers.

    Data Logging
    The unit is capable of performing data logging from the eight universal inputs, power and battery voltage. The data logging is stored in nonvolatile memory. A real-time clock is also included to time stamp logged data and to schedule reports. The unit is capable of sending automatic reports on a programmable time basis (i.e. Send a report every x hours starting at time xx:xx). Reports may be sent via fax or e-mail, and will be sent to
    all destinations programmed to receive reports. The report comprises a cover page and the unit data, which includes the current conditions of each input, power status and battery condition. If the data logger is enabled and programmed to be sent with reports, a data log report will also be sent at this time. You have the additional option of retrieving the data logger information locally or remotely on demand. You can also have the Sensaphone 2000 call your PC and upload the entire data logger and event logger, storing the information in the Sensaphone 2000 database.

    Programming Interface
    Manager 2000 Windows-programming software is included to allow quick and easy access to all of the unit's programmable parameters. Sophisticated features such as real-time input monitoring, graphical bar and gauge displays, polling of multiple units and a database to store and query data logger information, all combine to provide a complete monitoring system. Internet options for creating web pages and delivering e-mail are also included. The Programming and Operation chapters provide step-by-step instructions on how to use all of the unit's features.

    Battery Backup
    The Sensaphone 2000 includes an internal UPS that automatically switches to battery backup in the event of an AC power failure. The battery in the Sensaphone 2000 is a 6 Volt 3.4AH rechargeable gel cell. This battery will keep the unit operating for approximately 10 hours when fully charged and under normal operating conditions. Note: The unit will not turn on unless AC power is connected, regardless of the condition of the back-up battery.

    Line Seizure
    Line seizure gives the 2000 unit the ability to "seize" the telephone line when it needs to dial out. For example, if an emergency occurs which puts the 2000 in alarm mode, the unit will be able to dial out even if a telephone has been left off the hook. To the right of the PHONE LINE jack is another labeled PHONE EXT. This jack can be used to share a phone line with other devices (telephone, fax machine, modem) and to give the 2000 priority in the event of an emergency. To make use of this feature you must have all the extension devices originate from the PHONE EXT. jack. Whenever the unit must make an alarm phone call, the unit will disconnect any current phone calls and seize the line for its own use. The unit will continue to seize the line until the alarm has been acknowledged.

    LED Indicators
    The LEDs provide on-site alarm and status information. Listed below
    are descriptions of how the LEDs work.
  • Inputs 1-8 and Power: LED Off: Input OK, LED Blinking: Unacknowledged alarm exists LED On: Acknowledged alarm exists
  • Battery: LED On: Battery condition OK, LED Blinking: Battery condition low, LED Off: Battery very low
  • System-On: LED On: System power on, LED Off : System power off
  • Phone: LED On: Unit is communicating on the phone line, LED Off: Unit is not using the phone line
  • Output: LED On: The output relay is ON, LED Off: The output relay is OFF

    Sensaphone 2000 Software Requirements
  • 486 or better computer (Pentium recommended)
  • 10 MB of free disk space
  • 32 MB or more of RAM
  • CD ROM drive
  • Microsoft Windows 98, ME, NT, 2000 or XP
  • Monitor
  • Mouse
  • Modem

    WebPage
    The Sensaphone 2000 software can generate a web page based on the information in your 2000 and post it on the internet at a programmable time interval. The web page can be created in both standard HTML and WML formats; the latter allows viewing on an internet-capable cell phone. The web page will include input and alarm information. If you have more than one Sensaphone 2000, a separate web page will be created for each. The web page is created every time a Sensaphone 2000 unit is polled. In this scenario your host computer would contact one or more Sensaphone 2000s, retrieve the I/O status and alarm information, then create the web page. The software then uploads the web page to a specified server and directory on the World Wide Web. Most internet service providers allocate several megabytes of space on their server for their subscribers to place their own web pages as part of the internet service contract. Contact your internet service provider for information. Note that a typical Sensaphone web page only uses about 60K of storage space. The Web Page feature requires that you have a computer running Windows 95, 98, ME, NT, or 2000. Internet providers which use proprietary software, such as America OnLine, cannot be used. Your internet service provider must support File Transfer Protocol (FTP).

    Installation
    When you receive the unit, carefully remove it from the box. Mounting tabs with holes are provided on the left and right sides of the enclosure. Mount the unit in a position that allows easy access to the input terminal block, battery compartment, on/off switch and the programming port. Also, there must be a power outlet and telephone jack close to the unit.

  • Specifications

    Specifications

    Sensaphone 2000
    Manufacturer:Sensaphone
    Manufacturer Product No.:FGD-2000
    Dialing Parameters:
  • Programmable call list for each input
  • Call progress monitoring: detect dial tone, busy signals & ringback
  • Programmable time between calls: 30 seconds to 60 minutes
  • Destinations:
  • 32 Destinations
  • 32-digit phone numbers, 64 character email addresses
  • Programmable 24x7 call schedule for each Destination
  • Inputs:
  • 8 Universal Inputs & 1 AC Power
  • Normally Open/Normally Closed dry contact, Pulse Count, Run Time accumulator
  • Compatible with 2.8K or 10K thermistors
  • 4-20mA current loop, or 0-5V DC analog
  • 10 bit resolution
  • Communication Methods :Programmable Voice, Fax, Cell Phone/Alpha Pager Text Message, Numeric Pager, E-mail, Web Page
    Custom Voice Messages:8 Input messages (4 seconds each), 1 site ID message (6 seconds)
    Data Logging:
  • 32,000 records, each with time and date stamp
  • Selectable Logging Interval: 1 second to 200 hours
  • Select channels to log: Inputs 1-8, AC Power, Backup Battery Voltage
  • Communication Ports:
  • RS-232 port for local programming
  • DB9 female DCE
  • 38,400 bps
  • Built-in Fax/Modem:
  • Data throughput 14,400 bps
  • 14,400 bps Fax
  • Protocols: V.32bis, V.32, V.22bis, V.22A/B, V.23, V.21, Bell 212A & 103
  • Local LED Indicators :
  • Inputs 1-8 Alarm Status
  • Power Alarm
  • Phone
  • Battery OK
  • Power Requirements :
  • External transformer 120VAC 60Hz 10W (UL-listed power supply)
  • 3.4Ah sealed rechargeable battery (included)
  • 10 hour battery backup
  • Output Relay :1
    Operating Temp Range :0° C - 50° C (32° F - 122° F)
    Humidity:0% - 90% relative humidity, non-condensing
    Size:12.1" W x 7.2" H x 1.6" D
    Weight:3 lbs.
    Certifications:FCC
    NEMA 4X Enclosure
    Manufacturer:Wiegmann
    Construction:14gauge type 304 steel
    Certifications:Geo UL, CSA, NEMA/EEMAC


    Important notes:
    Only defective exchanges for identical item within 30 days of purchase. No other returns allowed on this item. For defective returns after 30 days, please contact the manufacturer.
    Manufacturer contact information: Sensaphone Inc, Tel: (877) 373-2700 Ext 260

    Images/Video

    Mounting Dimensions  Front View / Rear View of the Connections  Setting up Dialout Destinations using the Software  Event Log Showing Acknowledgment ID 
    Mounting Dimensions  Front View / Rear View of the Connections  Setting up Dialout Destinations using the Software  Event Log Showing Acknowledgment ID 
    Sample Web Page  E-mail Path  How it Works   
    Sample Web Page  E-mail Path  How it Works   

    Reviews

    Accessories

    Sensaphone Outdoor Temperature Sensor  Sensaphone Outdoor Temperature Sensor  Sensaphone 24V Power Supply for 4-20mA Sensors   
    Sensaphone Outdoor Temperature Sensor  Sensaphone Outdoor Temperature Sensor  Sensaphone 24V Power Supply for 4-20mA Sensors   

    Related Items

    Sign-up for Exclusive Email offers 
    ORDERING INFO
    How to Order Track Your Package Shipping Returns Contact Us Customer Service Retail Store
    MORE INFO
    Getting Started Learning Center FAQ Dealers Customer Testimonials Affiliate Program
    OUR COMPANY
    About Us INSTEON Press Awards Employment Guarantees Security & Privacy
    STAY INFORMED
    Free Catalog Email Newsletter Forum RSS Site Map
    Have questions? Call us at 800-762-7846 (Mon-Fri 5am-7pm and Sat 6am-3pm PT) or send us a message
    Place your order by 3pm PT for same day shipping
    Copyright 1995-2014 SMARTHOME™
    Verisign Secure Site PayPal Acceptance Mark