Find Similar Products in:
|
|
|
| RCS Serial RS-485 Communicating Network Thermostat with LCD Display Screen |
| Item# 3001C |
|
|
|
|
|
|
Overview
|
- Works with dtandard gas/electric and heat pump HVAC systems including multi-stage units
- RS485 Network Interface
- Multi-menu screens and four LEDS with dynamic on-screen labels
- Dual setpoints (separate heat and cool)
- Supports up to 2 remote sensors
Essential Info
The TR60 RCS Serial RS-485 Communicating Network Thermostat Wall Display Unit connects to, monitors and controls an HVAC mechanical system via a standard thermostat connection. It provides typical thermostat control of a central heating and cooling HVAC system plus has the added feature of RS485 communications for remote control.The TR60 consists of two components, the Wall Display Unit (WDU) and the Thermostat Control Unit (TCU). Normal local control of the HVAC system is provided by the WDU with its typical thermostat like user interface. The TCU provides all HVAC mechanical systems outputs as well as the RS-485 remote systems interface. The WDU can display multiple screens for different functions of the thermostat; these include current room temperature, heating and cooling setpoints, system mode, manual fan mode, time, status information and much more. The thermostat has four LEDs that have dynamic on-screen labels that change with the screen being displayed. If you wish to montior temperature in a location other than where the WDU is mounted, up to two remote sensors can me wired in. The WDU and TCU connect to each other, via a 4-wire RCSLink (2 power, 2 data) using the existing thermostat wiring. The TCU connects to an automation system via cat-5 wiring.
Manuals/Software
What's Included
TS60 Wall Display Unit (WDU) ZCV1 HVAC Control Unit TR60 Quick Start Guide Documentation CD
|
More Info
|
HVAC Systems Compatibility
- Works with standard Gas/Electric or Heat Pump HVAC mechanical Systems
- 2-stage Heating, 2-stage Cooling for Gas/Electric systems.
- 3-stage Heating, 2-stage Cooling for Heat Pump systems.
- Fan selection for fan w/heat operation.
- Heat Pump Changeover selectable for Heat or Cool operation.
- Fuse protected relay outputs to the mechanical systems
Display Operation
- Thermostat control screen - Normally the thermostat displays the thermostat control screen, however, using the "Menu" button, you can access other screens and functions of the thermostat.
- Minimized Display Mode - Optionally, you can set the thermostat to show only the temperature in a minimized display mode. This mode can be set on or off in the thermostat "Users Settings" menu.
- Backlight - The thermostat has a backlit display for low light and night visibility. It can be set to remain on constantly, or to turn off after a 20-120 second delay. These are selectable in the User Settings menu.
- Status LEDs - The thermostat has four LED’s that displays status information. The LEDs have dynamic on-screen labels that change with the screen being displayed.
- Function Control Buttons - The thermostats buttons are "Soft Keys" meaning that they change functions when you change screens. The function of the button is defined by on-screen labels that are dynamic and change when you change screens
Heating or Cooling Setpoints The setpoints can be set from 50°F to 90°F (4°C to 32°C) for heating or 55°F to 99°F (10°C to 37°C) for cooling. Note that you cannot lower the cooling setpoint below the heating setpoint.Main Menu Selections
- Schedules - This screen is used to view and set the programmable setback schedules of the thermostat.
- User Settings - This screen is used to set the Clock, Filter Service, Maintenance Service, Screen Timeout, F/C mode, Sensor Calibration and Backlite/Display settings.
- Economy Settings - Sets the energy savings Home, Away and Vacation setback heating and cooling setpoints.
- Thermostat Info Screen - This screen shows the firmware versions of the Thermostat’ s Wall Display Unit and HVAC Control Unit, HVAC system type setup and RS485 network address.
- Optional Menu Items:
- For these to show up in the main menu list, they must be enabled in the Installer Settings.
- SmartVent - Control screens for the optional SmartVent fresh air venting system.
- Messaging - A messaging system to send messages to the TR60 via the RS485 network.
Thermostat Schedule Selection The thermostat has a day and time heating and cooling setpoint temperature adjustment scheduler. It provides a 4x7 schedule, which has four times a day for each day of the week, for which separate heating and cooling setpoints can be programmed. Copying a Day Schedule to another Day The Copy Schedule screen allows you to copy one day’s schedule to another day or group of days. Messaging The TR60 thermostat has the option to receive and display text messages up to 80 characters in length via the RS485 network. The message screen features navigation buttons to read new and old messages and delete them. Up to 16 messages can be stored in the thermostat. If more than 16 messages are received, the oldest is erased to make room for the newest message. New messages will turn on and flash the Alert LED and Mail Icon in the main thermostat screen. Viewing messages makes them "old" and turns off the indicators. If you view some, but not all new messages, the new message notification LED and icon will stay on. Special Heat Pump Mode An additional system mode, "EHEAT" for Emergency Heat will be displayed if the HVAC system type is set to Heat Pump. If there is a compressor failure with the Heat Pump system, setting the mode to EHEAT will allow the stage 3 supplemental or aux heat (W1) to come on first whenever there is a call for heating. It also disables the compressor outputs (Y1/Y2) to preventfurther damage to the HVAC system. Schedule Modes
- RUN Mode - In the run mode, the thermostat schedule is running and setpoints will change according the times and temperatures in the internal schedule.
- HOLD Mode - This holds the current temperature setpoint settings. The schedule operation is disabled.
- HOME Mode - This is an energy saving setback mode. When selected, the HOME mode setback heating and cooling setpoints are used. It also inhibits schedule operation. HOME mod e setpoints are set in the Main Menu "Economy Settings" submenu.
- AWAY Mode - This is an energy saving setback mode. When selected, the AWAY mode heating and cooling setback setpoints are used. It also inhibits schedule operation. AWAY mode setpoints are set in the Main Menu "Economy Settings" submenu.
- VACATION Mode - This is an energy saving setback mode. When selected, the VACATION mode heating and cooling setback setpoints are used. It also inhibits schedule operation. VACATION mode setpoints are set in the Main Menu "Economy Settings" submenu.
|
Specifications
|
Specifications | |
| General | | Manufacturer: | Residential Control Systems | | Manufacturer Product No.: | TR60 (includes TS60 Wall Display Unit and ZCV1 HVAC Control Unit | |
| TS60 Wall Display Unit | | Dimensions: | 5.7" W x 4.0" H x 1.2" D | | Display: | Graphical LCD, 2.75" W x 1.5" T, 64x128 pixel | | Backlight: | Yes, blue/white, Controllable, on, off, timeout | | Contrast: | Adjustable on screen | | Buttons: | Six (6) | | LEDs: | Four (4): three (3) green, one (1) red | | Remote Sensors: | Two (2), two wire, remote primary, averaging | | Power: | 12VDC from HVAC Control Unit | |
| ZCV1 HVAC Control Unit | | Dimensions: | 8.0" T x 6.0" W x 1.5" D | | HVAC System Type Compatible: | Standard (gas/electric) or Heat Pump | | Multistage System Compatible: | Standard HVAC Systems: 2 stage heating, 2 stage cooling Heat Pump Systems: 3 stage heating (2 compressor, 1 aux heat), 2 stage cooling | | Heat Pump Change Over Valve: | Selectable change over with cool or with heat (O or B) | | Communications: | RS485 Half Duplex 2 wire (plus ground) | | Power: | 24VAC from HVAC system |
|
Images/Video
|
|
|
Reviews
|
|
|
Related Items
|
Customers Also Bought
|
|
|
|
|