| General |
| Brand: | INSTEON |
| Manufacturer Product No.: | 2478D, INSTEON SwitchLinc Dimmer (Dual-Band) |
| UPC: | White - 2478D: 813922012231 Ivory - 2478D: 813922012255 Almond - 2478D: 813922012248 |
| Patent No.: | U.S. Patent No. 7,345,998, International patents pending |
| Warranty: | 2 years, limited |
| Operation |
| On-Levels: | 32 locally, increments of 1% with software |
| Ramp Rates (full-ON to full-OFF): | 0.125 to 9 seconds if programmed locally, 0.125 seconds to 8 minutes if programmed remotely |
| LED Indicator: | 9 White LEDs, Optional Green, Blue, Amber, or Red with #2400L kit |
| Operation Modes: | INSTEON only, X10 only, INSTEON and X10 Combo Mode |
| Combo Mode Message Order: | INSTEON, INSTEON cleanup, X10 |
| Multi-Way Circuit Support: | One SwitchLinc Dimmer controls load, Cross-Link any number of SwitchLinc Dimmers or other INSTEON Controllers |
| Setup Memory: | Non-volatile EEPROM |
| INSTEON Features |
| INSTEON Addresses: | 1 hard-coded out of 16,777,216 possible |
| INSTEON Links: | 417 |
| INSTEON Powerline Frequency: | 131.65 KHz |
| INSTEON Minimum Transmit Level: | 3.2 Vpp into 5 Ohms |
| INSTEON Minimum Receive Level: | 10 mV |
| INSTEON Messages Repeated: | Yes |
| Radio Frequency: | 915 MHz |
| Mechanical |
| Paddle Type: | True rocker action |
| Wire Nuts: | 4 included |
| Mounting: | Mounts in single or multiple-ganged junction box. Control 200 W less load for each immediately adjacent SwitchLinc Dimmer installed. For example, 600 W load control becomes 400 W with another dimmer to the immediate right or left. Use a triple-gang box with a mechanical switch in the center to avoid de-rating. |
| Operating Conditions: | Indoors, 32 to 104° F, up to 85% relative humidity |
| Dimensions: | 4.1" H x 1.8" W x 1.2" D |
| Weight: | 3.6 oz |
| Electrical |
| Supply Voltage: | 100 to 277 Volts AC +/- 10%, 50 or 60 Hz, single phase |
| Neutral Wire: | Required |
| Power Wire Leads: | 6", 16 AWG, stranded,600V, 105°C insulation, ends stripped and tinned, Line (black), Load (red), Nuetral (white) |
| Ground Lead: | 6", 18 AWG, stranded, bare copper |
| Load Types: | Wired-in incandescent lighting devices |
| Maximum Load: | 600 Watts (uses 16-Amp triac dimmer) |
| Power Consumption: | < 1 Watt |
| Safety Approved | Intertek (ETL) |
Certifications: | FCC, IC Canada | | X10 Features (applies to power line only) |
| X10 Primary Address: | 1 optional (comes unassigned) |
| X10 Scene Address: | 255 possible |
| X10 Status Response: | Supported |
| X10 Resume Dim: | Supported (by setting Local On-Level to zero) |
| X10 Powerline Frequency: | 120 KHz |
| X10 Minimum Transmit Level: | 3.2 Vpp into 5 Ohms |
| X10 Minimum Receive Level: | 20mV into 5 Ohms |
| X10 Messages Repeated: | No |