| General |
| Brand: | Smarthome |
| Manufacturer Product No.: | 2475D, INSTEON In-LineLinc Dimmer |
| UPC: | 689076402743 |
| Patent No.: | U.S. Patent No. 7,345,998, International patents pending |
| Warranty: | 2 years, limited |
| Operation |
| On-Levels: | 32 locally, increments of 1% with software |
| Ramp Rates (full-ON to full-OFF): | 0.1 to 9 seconds if programmed locally, 0.1 seconds to 8 minutes if programmed remotely |
| LED Indicator: | Off when load is on and vice versa |
| Operation Modes: | INSTEON only, X10 only, INSTEON and X10 Combo Mode |
| Combo Mode Message Order: | INSTEON, INSTEON cleanup, X10 |
| Multi-Way Circuit Support: | Yes, as a receiver only that controls a load |
| Setup Memory: | Non-volatile EEPROM |
| INSTEON Features |
| INSTEON Addresses: | 1 hard-coded out of 16,777,216 possible |
| INSTEON Links: | 417 |
| INSTEON Powerline Frequency: | 131.65 KHz |
| INSTEON Minimum Transmit Level: | 3.2 Vpp into 5 Ohms |
| INSTEON Minimum Receive Level: | 10 mV |
| INSTEON Messages Repeated: | Yes |
| Mechanical |
| Wire Nuts: | 4 included |
| Mounting: | Mounts in single-ganged junction box or light fixture such as a recessed can light. |
| Operating Conditions: | Indoors, 32 to 104°F, up to 85% relative humidity |
| Dimensions: | 2.75" H x 1.75" W x 0.88" D (2.75" H without screw tabs) |
| Weight: | 3.6 oz |
| Electrical |
| Supply Voltage: | 120 Volts AC +/- 10%, 60 Hertz, single phase |
| Power Wire Leads: | 6", 16 AWG, stranded,600V, 105°C insulation, ends stripped and tinned, LINE (black), LOAD (red), NEUTRAL (white) |
| Ground Lead: | 6", 18 AWG, stranded, bare copper |
| Load Types: | Wired-in incandescent lighting devices |
| Maximum Amps: | 2.5 amps |
| Maximum Load: | 400 Watts |
| Power Consumption: | 0.78 Watts |
| Certification: | Safety tested for use in USA and Canada (ETL) |
| X10 Features |
| X10 Primary Address: | 1 optional (comes unassigned) |
| X10 Status Response: | Supported |
| X10 Resume Dim: | Supported (by setting Local On-Level to zero) |
| X10 Powerline Frequency: | 120 KHz |
| X10 Minimum Transmit Level: | 3.2 Vpp into 5 Ohms |
| X10 Minimum Receive Level: | 20mV into 5 Ohms |
| X10 Messages Repeated: | No |