|
Find Similar Products in:
|
|
|
| Evolve Guest Controls T-100R Wireless RF Z-Wave Communicating Thermostat |
|
Item# 12018
|
|
Price: Normally $129.99
Hot Deal $125.00
|
|
|
|
|
|
Free shipping on orders $200 and up details
|
|
Overview
|
- Z-Wave Certified
- Compatible with heat pump and standard HVAC systems
- 7-day programmable, 4 settings per day
- Backlit Graphical LCD display
- Setpoint display shows both heating and cooling
- Modes of operation: Off, Auto, Heat, and Cool
- New fan cycler feature
- Remote control for all thermostat functions
Essential Info
Controllable from any Z-Wave transmitter, The Evolve Guest Controls T-100R is a wireless RF, remote controllable, Z-Wave communicating thermostat. This unit is designed to work with the majority of typical HVAC systems. This thermostat is intended for use, in Z-Wave communicating systems, where remote monitoring, programming, and control are needed. Evolve's T-100R offers a 7-day programmable schedule with up to 4 different settings per day. Providing a very robust user interface, located on the face of the thermostat are 6 labeled buttons for manually controlling or programming your thermostat. Raise and lower temperatures manually or from anywhere in the world using network based automation control systems such as, the Cortexa Automation Controller or HomeSeer's HomeTroller. On-Screen labels assist in manually operating the thermostat, by acting as system indicators to show the user's current operating modes. An optional fan cycler feature can be used to automatically switch fans On/Off according to the pre-programmed user settings. To use this device you will replace your existing thermostat with the Evolve Guest Controls T-100R. The T-100R can be wall mounted or mounted to a single-gang junction box. There are four standard operating modes, along with one special operating mode intended for use in heat pump applications. These standard settings are Off, Heating, Cooling, and Auto. If using this thermostat in a heat pump HVAC system, the additional "EHEAT" setting can be used to help prevent damage to your HVAC system. In the event of a compressor failure, this mode will allow the supplemental Auxiliary heat to be triggered first, whenever heating is needed. Preventing further damage to your HVAC system is incredibly important in a situation like this, which is exactly what the "EHEAT" feature will do by disabling the compressor output. Maintenance and filter service indicators alert the user when a change of filter is needed or maintenance to the HVAC system. A minimum Run Time (MRT) is implemented to avoid uneven heating and cooling, as well as a Minimum OFF Time (MOT) which prevents rapid heating and cooling cycles while providing "short cycle protection" for compressors. A total of two external remote temperature sensors can be used to replace the internal sensor or to calculate an average between the two (sold Separately). This unit is powered by a 24VAC supply from the HVAC system and requires the connection of both the 24VAC (R) and 24VAC common (C) wires. This unit is not to be used for line voltage applications where control over 120/240VAC is required.
Important notes:
- Smarthome does not offer technical support on this product, please contact the manufacturer directly for all product support.
- Only defective exchanges for identical item within 30 days of purchase. No other returns allowed on this item. For defective returns after 30 days, please contact the manufacturer.
Manuals/Software
What's Included
1x - T-100R Wireless RF Z-Wave Communicating Thermostat, 7-Day Programmable 1x - Instalation Guide 1x - Operating Guide
|
More Info
|
Z-Wave is an interoperable two way RF mesh networking technology. Each main powered device in a Z-Wave network is designed to act as a repeater. Repeaters can re-transmit the RF signal to ensure that the signal is received by its intended destination by routing the signal around obstacles and radio dead spots. Smarthome offers a wide variety of Z-Wave compatible products which can be incorporated with the Evolve Z-Wave devices
HVAC System Compatibility Central HVAC systems or separate heating/cooling systems with separate RH/RC transformers (split). Standard gas/electric HVAC Systems: 2-stage heating, 2-stage cooling. Heat Pump HVAC Systems: 3-stage heating, 2-stage cooling. Fan system: Selectable for gas or electric heat systems. Heat Pump Change Over valve (reversing valve): Selectable for change over with heat or change over with cool (O or B output). Emergency Heat: In Heat pump mode, Emergency Heat mode is selectable from the thermostat. Compressor short cycle protection delay of 6 minutes (adjustable). Automatic heating and cooling changeover.
|
Specifications
|
| Specifications | | Manufacturer | Evolve Guest Controls | | Manufacturer Product No. | T-100R | | Power Requirements | Requires both 24VAC (R) and 24VAC common (C) wires from the HVAC System | | Voltage | 24VAC | | Wiring Requirements | Uses standard thermostat connections (C, R, W1,W2, Y1, Y2, G) | | Wiring | 18 AWG | | Remote Sensors | The T-100R supports up to 2 indoor remote sensors/Remote sensor can replace internal sensor or provide averaging |
|
Reviews
|
|
|
Related Items
|
Customers Also Bought
|
|
|
|
|
|